CTI Bonded Direct/Anti Fracture Test Results
I. BONDED DIRECT / ANTI-FRACTURE TESTS COMPOSEAL GOLD
Test ResultsCERAMIC TILE INSTITUTE
Minimum StandardBOND SHEAR STRENGTH: ASTM C-482 (mod) measures lateral psi at which installation loses bond under wet and dry conditions. using latex mod. Thin set mortar Using dry set mortar Dry: 3 days cover cured plus 4 days air cured: 71 psi 121 psi 50 psi 3 days cover cured plus 28 days air cured: 78 psi 111 psi 50 psi Wet: 3 days cover cured, 4 days air cured, PLUS total immersion in water for 7 days: 64 psi 92 psi 50 psi for 21 days: 63 psi 121 psi 50 psi for 93 days: 56 psi 95 psi 50 psi NOTE: Latex modified mortar of ten requires more than 7 days air cure for maximum strength. TENSILE STRENGTH: CTI/SE 5763
Measures psi pull strength at which installation
loses bond under dry and wet conditions.Using latex mod. mortar Dry: 3 days cover cured plus 25 days air cured: 75 psi 50 psi Wet: 3 days cover cured plus 4 days air cured PLUS 7 days immersed in water: 69 psi 50 psi 21 days immersed in water: 63 psi 50 psi 93 days immersed in water: 54 psi 50 psi
TOTAL SYSTEM PERFORMANCE: ASTM C627 (mod) Robinson Floor Tester/Split Slab .002 to .008" Tests for integrity of total installation no tile cracking/chipping or grout deterioration after successive cycles of increased load/stress over split substrate. Hydrostatic testing with 2" head of water performed at end of cycles. Number of completed cycles before failures:11 cycles (Gold adhesive bond)
9 cycles (Mortar bond)3 cycles
3 cycles
ROBINSON FLOOR TESTER: ASTM C627
(without split slab) Quarry tiles used.14 cycles: Extra Heavy Commercial Rating
II.
WATERPROOF TEST
HYDROSTATIC: FHA 4900.1 Sect. 615-5
Measures integrity of membrane after being subjected to 2 ft. head of water for 48 hours.no water
penetrationno water
penetration
INDENTATION RESISTANCE: FHA 4900.1
Tests membrane's chemical resistance to highly alkaline solutions such as soapy water.no water
penetrationno water
penetration
PUNCTURE RESISTANCE: FHA 4900.1
200 gram dart with small ball bearing point dropped from 3 ft. Simulates dropping of sharp edged tools onto membrane.no water
penetrationno water
penetration
FOLDING RESISTANCE: FHA 4900.1
Tests membrane for cracking in cold weather: 24o F for 24 hours, then membrane folded back on itself twice and then tested for cracks.no water
penetrationno water
penetration
FUNGUS and MICRO-ORGANISM RESISTANCE:
FHA 4900.1 plus Sec. C, or ANSI A136.1, K-6.4
Fungus and/or bacterial growth must actively be inhibited by membrane within 24 day period.no growth and
no water
penetrationno growth and
no water
penetration
DIMENSIONAL STABILITY: ASTM D-1204, -12o to 212o F
Membrane is tested for lineal change after being heated, and also after being cooled.
length:
width:-200 F 2120F
-.17% -.35%
-.29% -.30%.5%
.5%
SEAM STRENGTH: ASTM D-751
COMPOSEAL flexible vinyl cement, 24 hour cure47.7 psi/in. width 8 psi/in. width
BREAKING STRENGTH: ASTM D-751
Linear pressure at which membrane tears:
parallel : 1517 psi
parallel : 1603 psi170 psi
170 psi
ELONGATION: ASTM D-751
Amount membrane stretches before breaking:
parallel : 364%
perpend.: 462%20%
20%
HYDROSTATIC PRESSURE: ASTM D-751, A-1
Measures effect of sudden burst of high water pressure on membrane, such as water pipe burst. Results give psi at which membrane ruptures.116 psi 100 psi BREAKING STRENGTH: ASTM D-751
Linear pressure at which membrane tears:parallel : 1517 psi 170 psi
III.
OPTIONAL TESTS (Not required by CTI for Listing)
FLAMMABILITY: ASTM D568-77
Measures rate and extent of burning of bare membrane. Self extinguished.Burned .6 sec. after flame removed
OZONE RESISTANCE: ASTM D1149No crack, crazing or water penetration observed.
GAS PERMEABILITY (Methane) : ASTM D1434
Measures amount of methane gas that permeates membrane.GTR: 231.ml, Coeff: 3.6 Barrier
VOLATILITY TEST: ASTM D1203-89, Method A
Measures weight loss and distortions after accelerated aging of membrane..33% weight loss, no distortion
Compotite Corporation
(since 1938)
Los Angeles, CA
Copyright Compotite Corporation 1998